UK DATA CENTER

   
    • Network
   Data Center is connected to the Internet with highly redundant network through multiple Gigabit backbones having multiple    peering with other networks.

• Hardware Guarantee
   Servers deployed at the Data Center includes hardware replacement guarantee. In case of any hardware failure, the hardware    is immediately replaced.

• Security
   Data center located inside its own secure compound, with 2.4 and 3 meter fencing and electric gate entry Equipped & monitored    round the clock with closed circuits. Strict access controls are implemented including surveillance cameras, finger-print as well    as Keycard system in order to manage entries.

• Electrical Capacity
   Equal Power distribution (60 watts per sq. ft.- 80 watts per sq. ft). Each cabinet 4' x 6' gets 110 volt, 20 amp circuit. The main    power sums up to 480 volt, 3 phase. power supplies are now also activated in Multiple DC.

• Power
   In the unlikely event of a power outage from local power grid, all data centers' power systems are designed to run    uninterrupted with the help of Two 2000KW auto-switched power generators and centralized UPS systems. Generators are    regularly tested & can be used in emergency event of extended utility power outages.

• Precision Environment
   Computerized Fully master-planned rise system / HVAC pipe system / Electrically monitoration. HVAC (Heating Ventilation Air    Conditioning) systems are N+1 redundant, ensuring that a duplicate system can immediately come online in the event of an    HVAC system failure.

• Fire Protection System
   Wet Risers set in at every square position.FM-200 system is installed. The advanced fire protection system prevents fires from    spreading in the unlikely event one should occur.

• Technical Specifications
Datacenter Technical Specifications Own 5mW on-site sub-station
Datacenter Technical Specifications 2.5mW backup on-site sub-station
Datacenter Technical Specifications Perkins generator connected via ATS systems
Datacenter Technical Specifications 2 seperate fibre duct points into the building
Datacenter Technical Specifications N+1 PowerWave UPS system
Datacenter Technical Specifications N+1 Airedale Air Handling system
Datacenter Technical Specifications ~20c +/- 2c data floor temperature
Datacenter Technical Specifications 16 Amp feed per equipment rack
Datacenter Technical Specifications 24x7 secure entry via PAC-TAG system, with 4 layer entry
Datacenter Technical Specifications 24x7 qualified engineers available for remote hands service
Datacenter Technical Specifications 450mm heavy duty raised data flooring
   
Dell Servers BlueSquare Datacenter Fire suppression gas
Structured Cat6 shielded cabling Data Floor Structured Cat6 shielded cabling
External Air conditioning units Dell PowerEdge Server Rack of Dell PowerEdge Servers
Master electrical switchboard Server Rack Network operations centre
 